목록
이전글 다음글
KakaoTalk_20260403_135435192.jpg
AR715
AR715 Flow Meter/Pulse Counter

✔  Configurable measurement mode:
    - flow and balance measurement
    - pulse counter
    - incremental encoder (measurement of rotational speed, rotation            angle, displacement)
    - dispenser (dosing and simultaneous balance counting)
    - frequency measurement
    - remote display via RS485, MODBUS-RTU protocol, slave
✔  maximum measurement frequency:
    - 10 kHz - for flow, frequency, rotational speed
    - 30 kHz - for counter with PNP output
    - 100 kHz - for a counter with NPN output
✔  balance capacity 2x10^9 [units] with sign (-1999999999 ÷ 1999999999), 10 digits when the step position is 0
  universal pulse inputs (IN1, IN2) supporting flow meters, presence sensors, and encoders with the following outputs:
    - NPN open-collector
    - PNP open-collector
    - contact (reed, mechanical)
✔  additional inputs:
    - S - start/stop counting (counting enable)
    - R - counter/balance reset
    - B - binary input with programmable function
✔  2 relay outputs or, optionally, SSRs with programmable operating characteristics
✔  analog output 0/4–20 mA or 0/2–10 V (alarm, relay)
  built-in power supply for flow meters, encoders, and other 24 V / 50 mA sensors
  four-color LED display with adjustable brightness
✔  access to configuration parameters with or without password protection
✔  programming via a 4-button membrane keypad or digital interface
  programmable function key F and binary input for changing operating modes: keypad lock, unconditional manual mode for outputs, hold function for flow measurement (HOLD), start/stop of the dosing unit
✔  programmable communication options, alarms, and other configuration parameters
  methods of parameter configuration:
    - via the IP65 membrane keypad located on the front panel of the            device
    - via the RS485 port or PRG (AR956/955 programmer) and the free          ARSOFT-CFG software (Windows Vista/7/8/10), MODBUS-RTU
✔  software and a programmer enabling the display of measured values and quick configuration of individual or predefined parameter sets previously saved on a computer for reuse, for example in other devices of the same type (configuration duplication)
✔  high accuracy and resistance to interference in industrial environments
✔  96x48 mm panel-mount housing, IP65 from the front (with an accessory gasket or other, IP54 without a gasket), IP20 from the connector side